Flowmeter O2COMFORT

More comfort, less waste

Oxypoint’s O2COMFORT flowmeter is revolutionizing oxygen therapy in hospitals. Thanks to its innovative comfort mode, oxygen is delivered only during inhalation—precisely when the lungs need it. The device also offers a classic continuous mode, with an adjustable flow rate from 0 to 15 l/min.

Description
Proven savings
  • In comfort mode, oxygen is delivered only during inhalation, eliminating unnecessary oxygen flow during exhalation.
  • Even when patients leave their room for exams, bathroom visits, or therapy, oxygen delivery stops automatically—ensuring no oxygen is wasted between moments of use.
  • Two clinical studies demonstrated impressive savings:
    • 75% reduction in oxygen consumption in the cardiac surgery department of Antwerp University Hospital.
    • 40% reduction in the pulmonology department of Ghent University Hospital—even in COPD patients with shallow breathing.
  • Thanks to these savings, the investment in the O2COMFORT system typically pays for itself within 3 to 4 years.
Benefits of the O2COMFORT
  • Enhanced patient comfort – No drying of the nose or mucous membranes, and fewer nosebleeds.
  • Reduced infection risk – No need for humidifiers, significantly lowering the chance of bacterial growth.
  • Up to 75% oxygen savings – Without compromising the patient’s oxygen saturation.
  • Improved therapy adherence – More comfort leads to better compliance and faster recovery.
  • Automatic flow stop – Nasal cannula removed? Oxygen flow stops automatically and resumes when reattached.
  • Easy to use – Durable mechanical design with no electronics or batteries required.
  • Long service life – Minimum lifespan of 8 years; low maintenance.
  • Universally compatible – Available for all standard gas outlet types.Enhanced patient comfort – No drying of the nose or mucous membranes, and fewer nosebleeds.
  • Reduced infection risk – No need for humidifiers, significantly lowering the chance of bacterial growth.
  • Up to 75% oxygen savings – Without compromising the patient’s oxygen saturation.
  • Improved therapy adherence – More comfort leads to better compliance and faster recovery.
  • Automatic flow stop – Nasal cannula removed? Oxygen flow stops automatically and resumes when reattached.
  • Easy to use – Durable mechanical design with no electronics or batteries required.
  • Long service life – Minimum lifespan of 8 years; low maintenance.
  • Universally compatible – Available for all standard gas outlet types.